The Art of Fiberglass & Polyethylene, Engineered with Innovation and Precision for Lasting Performance.
Publish Date: October 1, 2026
The MST, also known as the MF Mechanical Septic Tank or Small Sewage Treatment System (SSTS), is a prefabricated FRP (fibreglass) sewage treatment unit for 40 to 150 PE (population equivalent), with Modified Standard B discharge. The MST is SIRIM certified to MS 2441-2:2014.
The system consists of one single FRP tank, with models ranging from MST-40 to MST-150 and no external piping between tanks. It is an active mechanical treatment system in which settling takes place in the lower part of the tank under anaerobic conditions, followed by an aerobic up-chamber activated sludge stage. Air is pumped through diffusers by air blowers, using an upflow activated sludge treatment process.
The MST is a separate product line from the passive Bio-Filter systems for 6 to 30 PE. It is designed for small developments and temporary or permanent domestic sewage treatment applications, including residential and other suitable small-scale projects. The system is intended for domestic sewage.
Mui Fatt is a SPAN-registered supplier, and the system is built to IWK guidelines. The quality system is ISO 9001:2015.
The MST was the first brand certified under the SIRIM product certification scheme.
The MST uses an upflow activated sludge process. Wastewater first passes through an anaerobic settling stage, followed by an aerobic aeration stage where diffused air is introduced. The treated wastewater then passes through the clarification stage before discharge.
The MST range covers treatment requirements from 40 to 150 PE. Select the model according to the calculated population equivalent for the project.
| Model | PE | Capacity (L) | Tank Length |
|---|---|---|---|
| MST-40 | 40 PE | 6,081 L | 1,537 mm |
| MST-50 | 50 PE | 8,105 L | 2,047 mm |
| MST-60 | 60 PE | 10,156 L | 2,561 mm |
| MST-70 | 70 PE | 12,191 L | 3,074 mm |
| MST-80 | 80 PE | 14,229 L | 3,587 mm |
| MST-90 | 90 PE | 16,275 L | 4,100 mm |
| MST-100 | 100 PE | 18,388 L | 5,014 mm |
| MST-120 | 120 PE | 22,384 L | 5,639 mm |
| MST-140 | 140 PE | 26,471 L | 6,666 mm |
| MST-150 | 150 PE | 28,517 L | 7,179 mm |
Common dimensions: 2,400 mm width, 2,650 mm height, 2,000 mm water level and 150 mm inlet/outlet pipe diameter. Desludging is required once every 2 years.
Population equivalent (PE) is used to determine the required treatment capacity. The selection guide uses 1 PE = 60 g BOD5 per person per day at 200 litres per day as the Malaysian design basis.
| Source | PE Basis |
|---|---|
| Typical house | 5 PE per house |
| Factory worker | 0.3 PE per worker |
| Office | 0.03 PE per m² of gross floor area |
For example, a project with 100 factory workers represents 30 PE, while 500 m² of office gross floor area represents 15 PE. The combined requirement is 45 PE. Because this exceeds the 30 PE Bio-Filter ceiling, the example moves into the MST range, with MST-50 indicated in the selection guide.
The MST supply includes the tank, primary and aeration sections, a built-in air diffuser, and the transfer pipe, VCP pipe and inspection chamber combined into the unit. This reduces the need for additional piping work between the treatment components on site.
The integrated arrangement also contributes to the system's stated 20–30% space saving compared with comparable systems.
The MST supply includes the treatment tank and integrated components required for the selected PE capacity, together with the relevant product documentation and submission support.
The typical lead time is 4 to 7 working days.
Under standard site conditions, the MST system can be installed in one day. The integrated tank arrangement reduces the amount of additional piping work required on site.
Mui Fatt can assist with the IWK and SPAN submission process for applicable MST projects. Submission support covers the required drawings and documentation needed for the approval process.
Free submission drawings are available to support the submission process. Contact Mui Fatt with the project's PE requirement to discuss the required system, drawings and submission documents.
The MST system carries a 5-year warranty against manufacturing defects. The warranty covers workmanship and does not cover misuse or installation that does not follow the installation manual.
Design life: 15–20+ years for the composite.
Desludging: once every 2 years.
Modified Standard B is the treated-water quality limit the MST is designed to meet before discharge. Under MS 2441-2:2014, Clause 6.1.2, the effluent is tested over three test periods and must meet the following limits:
| Parameter | 90% of Samples | Maximum for Any Sample |
|---|---|---|
| BOD5 | ≤ 20 mg/L | ≤ 35 mg/L |
| Suspended solids (SS) | ≤ 50 mg/L | ≤ 75 mg/L |
| COD | ≤ 120 mg/L | ≤ 160 mg/L |
| Oil and grease (O&G) | ≤ 5 mg/L | ≤ 7.5 mg/L |
Standard B applies to septic tanks from 5 to 30 PE, while Modified Standard B applies to small sewage treatment systems (SSTS) from 31 to 149 PE.
The MST achieves the required treatment through an anaerobic sludge blanket in the lower zone followed by an aerobic activated sludge stage in the up chamber. Air is supplied through diffusers, after which the flow passes to a clarifier. A scum baffle and set effluent weir length help prevent suspended solids from carrying over into the discharge.
The MST / Small Sewage Treatment System covers 40 to 150 PE, with models from MST-40 to MST-150.
The required model depends on the project's calculated population equivalent (PE). Select the model according to the required PE capacity. The available models, capacities and tank lengths are shown in the MST model table above.
PE is calculated using the applicable wastewater loading basis. The selection guide uses 1 PE = 60 g BOD5 per person per day at 200 litres per day, with 5 PE per typical house, 0.3 PE per factory worker and 0.03 PE per m² of office gross floor area.
For example, 100 factory workers represent 30 PE, while 500 m² of office gross floor area represents 15 PE, giving a total of 45 PE. Since this exceeds the 30 PE Bio-Filter ceiling, the applicable MST model for this example is MST-50.
Rental terms are available on request and depend on the selected MST model and rental period.
View MST Small Sewage Treatment System Rental
An MST is used when the treatment requirement is above 30 PE. The PE Bio-Filter covers 6 to 18 PE, the FRP Bio-Filter covers 8 to 30 PE, and the MST range covers 40 to 150 PE.
Two air blowers are required as one duty blower and one standby blower. The air blowers and control panel are provided by the contractor or installer, together with the required mechanical and electrical connections.
Mui Fatt supplies the MST treatment unit and its integrated components, while the contractor or installer is responsible for the required civil, structural, mechanical and electrical works.
Mui Fatt's supply includes the primary and aeration tank, built-in air diffuser, transfer pipe, VCP pipe and inspection chamber integrated into the unit, together with the SIRIM certificate and product documentation.
The contractor or installer provides the base slab, concrete plinth foundation, screen and distribution chambers, air blowers, control panel, mechanical and electrical connections, excavation, shoring, backfill, fencing, site works and CCTV inspection with the IWK officer.
Yes. The MST is intended for domestic sewage and is designed for small developments requiring treatment from 40 to 150 PE.
No. The MST uses one single FRP tank, with the transfer pipe, VCP pipe and inspection chamber integrated into the unit. There is no external piping between separate treatment tanks.
Modified Standard B is the treated-water quality limit that the MST is designed to meet before discharge. See the Modified Standard B Effluent Requirements section above for the applicable limits under MS 2441-2:2014, Clause 6.1.2.
Yes. Mui Fatt provides IWK and SPAN submission support, including free submission drawings and the required product documentation for the submission process.
The MST carries a 5-year warranty against manufacturing defects. The warranty covers workmanship only and does not cover misuse or installation that does not follow the installation manual.
The stated composite design life is 15–20+ years, and the MST requires desludging once every 2 years.
Technical specifications and product information on this page are attributed to Danny Ng Shin Lai, Director & Lead Composite Technical Specialist, and the Mui Fatt Technical Engineering Support Team. Danny Ng studied Materials Science and Engineering at UC Berkeley and oversees technical design, composite fabrication standards, engineering design, and technical compliance for FRP/GRP products, including compliance with MS 1390:2010 and MS 2441-2:2014 in Malaysia.
Have a wastewater project requiring treatment from 40 to 150 PE? Send Mui Fatt your calculated PE requirement and project details to discuss the appropriate MST model, system documentation and submission requirements.
Mui Fatt can provide drawings, SIRIM certificates and IWK submission documents on request.
Looking for a Small Sewage Treatment System (MST) for your project? Contact Mui Fatt to discuss your required PE capacity, project requirements and wastewater treatment needs.
Mui Fatt provides Small Sewage Treatment Systems covering 40–150 PE, with models from MST-40 to MST-150.
Working hours: Monday to Friday, 8:30am to 5:30pm
Send us your project's PE requirement to discuss the suitable MST system, available models, drawings and submission documentation.
Talk to our team today. We’ll help you find the right solution for your business needs.
Get a Quote